laser-induced breakdown spectroscopy; femtosecond laser filament; plasma temperature; electron density;INDUCED BREAKDOWN SPECTROSCOPY
Laser-induced breakdown spectroscopy (LIBS), which is also known as laser-induced plasma spectroscopy (LIPS), is a very promising spectral analysis technique for detecting elemental composition. The possibility of remote operation of LIBS is one of the properties, which expands the application scope of this technique. The remote LIBS technique is based on a long-range lens. With the increase of focusing distance, it is difficult to tightly focus laser pulse due to the diffraction limits. The size of focusing spot increases with focusing distance increasing. This will require extremely high laser energy. Femtosecond laserfilamentation due to optical Kerr effect can be applied to the remote LIBS. During the filament propagation, the waist of laser beam is close to a constant value. The laser intensity inside the filament is about 10(13) W/cm(2) (intensity clamping). The intensity is sufficient to ablate sample and produce the plasma. It can overcome the influence of the diffraction limit in nanosecond LIBS. Although many researchers have studied the femtosecond geometrical focusing and femtosecond filamentation LIBSs, the spectral characteristics have not been completely understood. In this paper, we study the femtosecond laser filament-induced Cu plasma spectroscopy. Femtosecond laser system is an ultrafast Ti:sapphire amplifier (Coherent Libra). The full-width at the half maximum is 50 fs at a wavelength of 800 nm with a repetition rate of 1 kHz and its output energy is 3.5 mJ. A quartz lens with a focal length of 1 m is used to focus the laser to generate a filament channel. The spectral intensity of produced Cu plasma along the filament channel is measured by using the optical emission spectroscopy, and the distribution of Cu(I) intensity versus the distance between sample and focused lens is obtained. The results indicate that in a longer distance range along the filament, plasma spectroscopy has stronger emission due to the intensity clamping effect in femtosecond laser filamentation. In addition, we also calculate the plasma temperature and electron density by using the Boltzmann plot and the Stark broadening. The plasma temperature and electron density along the filament channel can be divided into three main regions:region 1) from 950 mm to 970 mm, in which the plasma temperature and electron density increase with the increase of distance; region 2) from 970 mm to 1030 mm, in which the change of plasma excitation temperature is opposite to the change of electron density; region 3) from 1030 mm to 1050 mm, in which the plasma temperature and electron density decrease with the increase of distance.